ACS PS-Serie

StandardOption 
Features
  • 1 and 3 phase
  • Variable voltage and frequency for net simulation
  • Voltage peaks, swells and drop out
  • Variable current limits and cut off
  • Wave option for simulation of non sinusoidal signals
  • Display and measurement values Urms, Irms, P, S, PF, Ipk
  • Phase shifted power on
  • Interface RS232 and Software ACS Control

  • AC and DC operation
  • Frequency range 1 Hz – 500 Hz (up to 2 kHz option)
  • Output voltage 0 V – 300V AC, 0 V – 425 V DC
  • Voltage range up to 500 Vrms (option HV), 750 Vrms (option XHV)
  • Distortion factor 0,1 % (linear amplifier)
  • Load unit for energetic recovery operation (option)
models power phases frequency AC voltage AC power Peak-Strom
ACS-0400-PS 400 VA / 500 * VA 1 1 Hz - 500 Hz 0 V - 150 V / 0 V - 300 V 3 A / 1,5 A 8 A
ACS-0800-PS 800 VA / 1,000 * VA 1 1 Hz - 500 Hz 0 V - 150 V / 0 V - 300 V 6 A / 3 A 20 A
ACS-1600-PS 1,600 VA / 2,000 * VA 1 1 Hz - 500 Hz 0 V - 150 V / 0 V - 300 V 12 A / 6 A 40 A
ACS-2200-PS 2,200 / 2,750 * VA 1 1 Hz - 500 Hz 0 V - 150 V / 0 V - 300 V 16 A / 8 A 60 A
ACS-3000-PS 3,000 / 3,750 * VA 1 1 Hz - 500 Hz 0 V - 150 V / 0 V - 300 V 20 A / 10 A 80 A
ACS-4600-PS 4,600 / 5,750 * VA 1 1 Hz - 500 Hz 0 V - 150 V / 0 V - 300 V 30 A / 15 A 100 A
ACS-6000-PS 6,000 VA 1 1 Hz - 500 Hz 0 V - 150 V / 0 V - 300 V 40 A / 20 A 120 A
ACS-1200-PS 3 x 400 VA / 500 * VA 3 1 Hz - 500 Hz 3x 0V - 150V / 3x 0V - 300V 3x 3 A / 3x 1,5 A 3 x 8 A
ACS-2400-PS 3 x 800 VA / 1,000 * VA 3 1 Hz - 500 Hz 3x 0V - 150V / 3x 0V - 300V 3x 6 A / 3x 3 A 3 x 20 A
ACS-4800-PS 3 x 1.600 VA / 2.000 * VA 3 1 Hz - 500 Hz 3x 0V - 150V / 3x 0V - 300V 3x 12 A / 3x 6 A 3 x 40 A
ACS-6600-PS 3 x 2.200 / 2,750 * VA 3 1 Hz - 500 Hz 3x 0V - 150V / 3x 0V - 300V 3x 16 A / 3x 8 A 3 x 60 A
ACS-9000-PS 3 x 3.000 VA / 3.750 * VA 3 1 Hz - 500 Hz 3x 0V - 150V / 3x 0V - 300V 3x 20 A / 3x 10 A 3x 80 A
ACS-13800-PS 3 x 4,600 VA / 5,750 VA * 3 1 Hz - 500 Hz 3x 0V - 150V / 3x 0V - 300V 3x 30 A / 3x 15 A 3x 100 A